FAQs

FAQ for PLC Below:

Ans. Open PLC program >> Select PLC in tools >> Select PLC type >> Select model of PLC >> Ok.

Ans. Make sure PLC supply is On >> Connect micro USB cable to PLC >> Select transfer setup >> Connection test >> PLC detect successfully >> Ok >> Select compile >> Successfully Compile Ok >> Select write to PLC >> Select param+prog >> Execute.

Ans. Make sure PLC supply is On >> Connect micro USB cable to PLC >> Select transfer setup >> Connection test >> PLC detect successfully >> ok >> Select read from PLC >> Select param+prog >> Execute.

Ans. Open PLC program >> switch the PLC from run to stop mode >> Select Encryption tools >> Select which type of password you wants to set .
We can set :
1.Program Password
2.Download Password
3.Upload Password
4.Clock Password
5.PLC Code.

Ans. First of all give supply to PLC >> Connect micro USB cable to PLC >> Select transfer setup >> Connection test >> PLC detect successfully >> ok >> switch the PLC from run to stop mode >> Select clear memory >> Select PLC memory >> Execute.

Ans. First of all give supply to PLC >> Connect micro USB cable to PLC >> Select transfer setup >> Connection test >> PLC detect successfully >> ok >> switch the PLC from run to stop mode >> Select clock setting >> Select read PC time >> Set time.

Ans. Open PLC program >> Select compile >> Ok >> Select generate download file >> Give path to save file >> Ok.
For download generated file.
Open wecon PLC editor >> Select open >> Select generated file >> Select write to PLC >> Select param+prog >> Execute.

FAQ for HMI Below:

Ans. Open PLC program >> Select compile >> Ok >> Select Udisk download file >> Give path to save file >> Ok.
On HMI Press top right corner for 5 to 10 sec >> System Screen >> Update project.

Ans. PI Series - Project >> Project Settings >> HMI Model >> Ok.
LEVI Series- Open Setting >> Project Properties >> General >> Device type >> HMI Model >> Ok.

Ans. PI Series -Project >> Communication >> New >> Set communication, serial Port & Device Type >> Ok.
LEVI Series- Open Setting >> Communication >> New >> Set port & Device Type >> Ok.

Ans. PI Series -Make Sure HMI supply is on >> Open HMI Program >> Project >> Compile >> Connect downloading cable >> Download (If HMI is accessed, it will show [USB: Download] in [Download] menu) >> PC to HMI. Download via Ethernet cable- Press top right corner of HMI Screen >> Network >> Set HMI IP >> Connect Ethernet Cable >> Select PC Port Ethernet >> Set IP of HMI >> PC to HMI.
LEVI Series- Make Sure HMI supply is on >> Open HMI Program >> Tool >> Compile >> Connect downloading cable >> Download (If HMI is accessed, it will show [USB: Download] in [Download] menu) >> PC-> HMI.

Ans. PI Series - Make Sure HMI supply is on >> open PIStudio download. Exe directly >> Connect downloading cable (If HMI is accessed, it will show [USB: Download] in [Download] menu) >> Enter Password (If uploading Password set) >> HMI-> PC.
Decompile uploaded program
Open PIStudio >> Project >> Decompile >> Browse .wmt file >> Enter Project password (If uploading Password set) >> Decompile.
LEVI Series- Make Sure HMI supply is on >> open download. Exe directly >>>> Connect downloading cable (If HMI is accessed, it will show [USB: Download] in [Download] menu) >> Enter Password (If uploading Password set) >> HMI-> PC
Decompile uploaded program
Open LEVIStudioU >> Tool >> Decompile >> Browse .hmt (General Series) or .ehmt (2000 Series) file >> Project password (If uploading Password set) >> Decompile.

Ans. PI Series- Open PIStudio >> Project Setting >> Designer Password >> ok.
LEVI Series- Open LEVIStudioU >> Setting >> Project Properties >> Screen Security >> Designer Password.

Ans. PI Series- Open HMI Program >> Project >> Udisk Download >> Browse path of USB-disk. On HMI Press top right corner for 5 to 10 sec >> System Screen >> Update project.
LEVI Series- Open HMI Program >> Tool >> Udisk Download >> Browse path of USB-disk. On HMI Press top right corner for 5 to 10 sec >> System Screen >> Update project.

Ans. PI Series- Open PIStudio Download (If HMI is accessed, it will show [USB: Download] in [Download] menu) >> Sync HMI clock with PC.
LEVI Series- Open Download (If HMI is accessed, it will show [USB: Download] in [Download] menu) >> Sync HMI clock with PC.

Ans. Press top right corner of HMI for 5 to 10 sec >> System Screen >> System Setting >> Date/Time.

Ans. Open Download (If HMI is accessed, it will show [USB: Download] in [Download] menu) >> Recalibration >> Press + Sign until sound of beep. On HMI Press top left corner for 5 to 10 sec. >> Press + Sign until sound of beep.

Ans. PI Series -Create New Project >> select HMI Model and Angle >> ok.
LEVI Series- Create New Project >> Select HMI model as Model_TV (i.e. LEVI 2070_TV).

FAQ for Yudian ATC KHOAT Below:

From right side to left side, the first, second, third and fourth digit of AOP individually indicate the alarm output terminal of HIAL, LoAL, HdAL, and LdAL. 0 shows no output. 1, 2, 3 or 4 indicates alarm outputted to AL1, AL2, AU1 or AU2. For example,
AOP = 3 3 0 1
LoAL HdAL LoAL HIAL
It shows that HIAL is sent to AL1, LoAL has no output, HdAL and LdAL are sent to AU1. Note 1: When AUX is used as auxiliary output in bidirectional (heating/refrigerating) control, alarm to AU1 and Au2 won’t work.
Note 2: Installing L5 dual relay output module in ALM or AUX can implement AL2 or AU2 alarm.

In basic display status, press enter button (1st from left side) and hold for about 2 seconds can access Field Parameter Table. Pressing enter button can go to the next parameter. Enter 808 in LOC parameter. You can use shift button (2nd from left side) to move to the digit expected to modify. Press UP & DOWN key for increasing and decreasing digit value. Go to the INP parameter and select your input type according table.

Inp Input spec. Inp Input spec.
0 k 26 0~80ohm resistor input
1 S 27 0~400ohm resistor input
2/td> R/td> 28 0~20mV resistor input
3 Spare 29 0~100mV resistor input
4 E 30 0~60mV resistor input
0 k 26 0~80ohm resistor input
0 k 26 0~80ohm resistor input
5 J 31 0~500mV Voltage input
7 N 32 100~500mV Voltage input
10 Extended input specification 33 1~5V Voltage input
15 4 ~20mA (installed I4 in MIO) 34 0~5V Voltage input
16 0 ~20mA (installed I4 in MIO) 35 0~10V
20 Cu50 36 2~10V
21 pt100 37 0~20V

Programming of AI series instrument has uniform format of temperature-time-temperature, which means that temperature set for current Step will change to temperature set for next Step after the time set for the current Step. The unit of temperature set is and the unit of time set is minute. The following ℃example includes 5 steps, which is linear temperature heating up, constant temperature, linear temperature cooling down, jump cycling, ready, Hold and event output.
StEP1: C01=100 , t01=30 Start linear temperature heating up from 100 , and the time needed is 30 ℃ minutes.
StEP2: C02=400 , t02=60 Raise temperature to 400 , slope of ℃ raising curve is 10 /minute, and the time for temperature to remain constant is 60 minutes.
StEP3: C03=400 , t03=120 The Step for temperature cooling down, slope of cooling curve is 2 /minute, and the time ℃ needed is 120 minutes.
StEP4: C04=160 , t04=0 The program get in Hold state, and run operation executed by operator is needed for the program to continue running to Step 6.
StEP5: C05=100 , t05=-1 Alarm 1 is switch off, and jump to StEP1 to start from beginning. For would stop by entering -121 in last Txx.

AIJK 3=Three Phase four wire star connection
AIJK 6=Three Phase three wire delta connection

• Insert ATC CD
• Uninstall the previous drivers in device manager
• Click on update driver
• Give the path of your particular ATC product from CD drive
• Update the driver