loader
  • Accumulate mass, volume or length of medium, provide batch control over the accumulation. As batch controller, it has 4-bit accumulator for control and 12-bit accumulator for total sum individually.
  • Square root/no square root selectable ,8-digits accumulation value and 4-digits momentary process value, small signal cut-out can be set at any range.
  • AI-808H has temperature and pressure compensation, using for calculation for temperature and pressure compensation for general gas, saturated steam, superheated steam and liquid. The compensation calculation with the method of table look-up has high accuracy in the steam measurement application. Special function can be carried out by enhancing the compensation formula upon customers’ requirements.
  • Advanced computation algorithm assures high accuracy in the application of flow measurement even if the input frequency is very low.
  • Abundant functions such as retransmission, high/low alarm of momentary flow, temperature and pressure, abnormal signal detecting, and communication with computer are available.
  • Flow Input : Linear Voltage (0-5V DC OR 1-5V DC, Linear Current (4-20mA), Two Wire Transmitter Input
  • Temperature Input : RTD PT-100 OR Thermocouple (K,E,J) – For Temperature Compensation (Compensation possible with AI-808H)
  • Pressure Input :  0-5V DC OR 1-5V DC, 4-20mA – For Pressure Compensation (Compensation possible with AI-808H)
  • Display : Flow Rate, Accumulated or Total Flow, Pressure & Temperature
  • Output for Batch Control : Relay
  • Alarm : High & Low Alarms for Flow, Temperature & Pressure
  • Communication : RS-485 (Plug-in Module)
  • ReTransmission O/P : Linear current or voltage (SV OR PV)
  • Power Supply : SMPS 100~240VAC/DC‚ 50 Hz OR 24 V DC
  • Panel Cutout Size : 96×96mm, 72×72mm, 48×48mm, 48×96mm, 96×48mm, E5 Din Rail mounting, A6 LCD Display
  • spacing : 0pt’>Modularized and configurable inputs, the flow input can be 1-5V, 0-5V, 4-20mA or frequency signal, and special user defined input specification is also available. The temperature input can be configured to Pt100 RTD, K, E, J type thermocouple, voltage, or current signal. The pressure input can be various voltage or current signal.
  • Abundant functions such as retransmission, high/low alarm of momentary flow, temperature Chopard Replica Watches and pressure, abnormal signal detecting, and communication with computer are available.
  • Square root/no square root selectable, 8-digits accumulation value and 4-digits momentary process value, small signal cut-out can be set at any range.
  • Model no. AI-708H, AI-708H-A6, AI-808, AI-808H-A6

Leave a Reply

Your email address will not be published. Required fields are marked *

Inquire Now